MC_GROUP_READ_ERROR (218)
Zastosowanie: |
PLC |
SIM |
Opis skrótowy:
This Function Block describes general axes group errors not relating to the Function Blocks. This is an administrative FB, since no movement is generated.
wejścia (1 sztuk):
nr |
typ |
impuls |
oznaczenie |
uwagi |
1 |
B |
nie | Enable | Get the value of the GroupErrorID continuously while enabled |
wyjścia (5 sztuk):
nr |
typ |
impuls |
oznaczenie |
uwagi |
1 |
B |
nie |
Valid | True if valid outputs are available |
2 | B | nie | Busy | The FB is not finished |
3 | B | nie | Error | Signals that an error has occurred within the function block |
4 | INT | nie | ErrorID | Error identification |
5 | INT | nie | GroupErrorID | The value of the axes group error. These values are vendor specific. |
ustawienia:
opis działania:
Examples are (software) limit switch exceeded or single axis error in GroupStandby state.
Używane rejestry R i znaczniki M: brak