MC_GROUP_DISABLE (212)
Zastosowanie: |
PLC |
SIM |
Opis skrótowy:
This Function Block changes the state for a group from GroupDisabled to GroupStandby. This is an administrative FB, since no movement is generated.
wejścia (1 sztuk):
nr |
typ |
impuls |
oznaczenie |
uwagi |
1 |
B |
tak | Execute | Start the change of state at the rising edge |
wyjścia (4 sztuk):
nr |
typ |
impuls |
oznaczenie |
uwagi |
1 |
B |
nie |
Done | AxesGroup in state GroupDisabled |
2 | B | nie | Busy | The FB is not finished |
3 | B | nie | Error | Signals that an error has occurred within the function block |
4 | INT | nie | ErrorID | Error identification |
ustawienia:
opis działania:
- The command does not influence the power state of any of the single axes in the group
Używane rejestry R i znaczniki M: brak