MC_GROUP_READ_ACTUAL_ACCELERATION (216)
Zastosowanie: |
PLC |
SIM |
Opis skrótowy:
This Function Block returns the actual acceleration in the selected coordinate system of an axes group. This is an administrative FB, since no movement is generated.
wejścia (2 sztuk):
nr |
typ |
impuls |
oznaczenie |
uwagi |
1 |
B |
nie | Enable | Get the actual acceleration in the selected coordinate system of the axes group continuously while enabled |
2 | INT | nie | CoordSystem | Reference to the coordinate system used: ACS, MCS, or PCS |
wyjścia (11 sztuk):
nr |
typ |
impuls |
oznaczenie |
uwagi |
1 |
B |
nie |
Valid | True if valid outputs are available |
2 | B | nie | Busy | The FB is not finished |
3 | B | nie | Error | Signals that an error has occurred within the function block |
4 | INT | nie | ErrorID | Error identification |
5 | REAL | nie | Acc_1 | Current acceleration of the group: - in ACS the acceleration of the different axes - in MCS and PCS it provides the acceleration of the TCP |
6 | REAL | nie | Acc_2 | |
7 | REAL | nie | Acc_3 | |
8 | REAL | nie | Acc_4 | |
9 | REAL | nie | Acc_5 | |
10 | REAL | nie | Acc_6 | |
11 | Real | nie | PathAcceleration | Current combined path acceleration of the TCP. |
ustawienia:
opis działania:
Używane rejestry R i znaczniki M: brak