MC_Reset


Application:

PLC

SIM

 

Short description:

This Function Block makes the transition from the state ‘ErrorStop’ to ‘Standstill’ or ‘Disabled’ by resetting all internal axis-related errors – it does not affect the output of the FB instances.


Inputs (1):

no.

type

impulse

mark

notes

1

B

yes Execute Resets all internal axis-related errors

 

Outputs (4):

no.

type

impulse

mark

notes

1

B

no

Done

'Standstill’ or ‘Disabled’ state is reached
2 B no Busy The FB is not finished and new output values are to be expected
3 B no Error Signals that an error has occurred within the Function Block
4 INT no ErrorID Error identification

 

 

Settings:

no.

type

mark

notes

1 INT AxisID associated axis number


Operation description:



Notes: none

 

R registers and M markers used: none