Device_M_Send (10019)


Application:

 

SIM

 

Short description:

Function that writes values to the controller markers.
 

Inputs (1 + number of markers):

no.

type

impulse

mark

notes

1 BOOL no enable enables data reading
2 BOOL no mn marker mn value


Outputs (4):

no.

type

impulse

mark

notes

1 BOOL no busy reading in progress
2 BOOL no done reading is done
3 BOOL no err error
4 INT no err_id error ID (0 - no error, 1 - unknown error, 2 - no connection, 3 - communication error)

 

Settings:

no.

type

mark

notes

1 INT Number initial marker address to write
2 INT Size number of markers to write


Operation description:


Notes:


R registers and M markers used: none